CORROSION CONTROL AT YOUR FINGERTIPS!
Request a Quote – info@smart-structures.com
Call Now 561-988-0070
ECI-2
The ECi-2 is a monitor for steel-reinforced concrete structures, using non-destructive evaluation (NDE) to provide early warning of conditions that can lead to cracking, spalling, delamination, and other deterioration. The NetCon-10 is a connection module. It helps organize large networks of corrosion monitors and guards them against voltage spikes.
The ECi-2 is comprised of sensor electrodes and processing electronics, integrated within a molded plastic enclosure. It monitors five key factors in the corrosion of steel-reinforced concrete structures – linear polarization resistance, open circuit potential, resistivity, choloride ion concentration, and temperature. In this way, the ECi-2 provides substantially more comprehensive data than prior generations of sensors. That, in turn, reveals correlations among the causes and signs of corrosion, and yields a fuller, more certain picture of the threat.
UNDERGROUND REFERENCE ELECTRODE
Bagged or underground electrodes are the perfect choice for permanent underground reference electrodes because they have proven long term durability. There is very little contact resistance between the soil and the large surface area of the bag even in semi-dry soils.
Smart Structures offers extended life Ag/AgCl reference electrodes with a design life of 50 years or more. The 4” diameter bags are easily installed at new construction sites including auger cast piles and deep foundations.
CORROSION COUPON SENSOR
The Corrosion Coupon Sensor is an autonomous half-cell potential (HCP) monitoring system that uses a reference electrode and coupon assembly placed directly in concrete in multiple strategic locations throughout a structure during construction. Location examples include next to reinforcing steel within splash zones in bridges over water, and areas subject to water runoff or having exposure to chloride sources.
The embedded instrumentation uses low power localized signal conditioning for longer cable runs to provide for improved reading fidelity. The system utilizes the latest state-of-the-art, low power high impedance analog electronics instrumentation design, layout, and mil-spec fabrication practices. This helps protect the reference electrode from unwanted and damaging leakage currents, and provides for maximum service life.
The deployment strategy for using the embedded HCP assemblies in long term monitoring applications, is to provide for a statistically significant amount of measured data points. By having a large sample set of points available on any given structure, the data dependency on any one measurement location using absolute reading levels for guidance is mitigated. Using this approach, an analysis can be made using nearest neighbor comparisons to monitor the overall trending of the population; ultimately to disqualify and discard any questionable readings, and track or segregate readings based on statistical standard deviations of the sample set. This is preferred because single measurement points are dependent on variables such as concrete mix design, temperature, salinity, moisture, etc.